On multi-objective optimal reconfiguration of MV networks in presence of different grounding

2015

The present work faces the traditional multi-objective optimal reconfiguration problem of a distribution grid including the safety issue in the objective functions. Actually, in many medium voltage networks still transformers with ungrounded neutral and with resonant grounded neutral coexist in the same area. This may be sometimes cause of problems during a single-line-to-ground fault if the ground electrodes of one or more cabins, initially designed for satisfying the safety conditions in a resonant grounded neutral network, after the reconfiguration are in a grounded neutral one or vice versa. In the paper a safety objective function is defined and the Non dominated Sorting Genetic Algori…

Mathematical optimizationOptimization problemGeneral Computer ScienceComputer science020209 energyDistribution gridGlobal grounding02 engineering and technologyFuzzy logiclaw.inventionMetallawMV network0202 electrical engineering electronic engineering information engineeringTransformerReconfiguration;MV network;Global grounding;Distribution grid;Genetic algorithmGroundbusiness.industryComputer Science (all)Control reconfigurationEarthing systemSettore ING-IND/33 - Sistemi Elettrici Per L'EnergiaGenetic algorithmvisual_artEmbedded systemElectrodeReconfigurationvisual_art.visual_art_mediumEvolution strategybusiness
researchProduct

Current transformers effects on the measurement of harmonic active power in LV and MV networks

2011

The harmonic active power is used to determine the location of polluting loads, the direction of harmonic power flow and to estimate how consequential a certain current harmonic source is. The highest uncertainties, when measuring harmonic active power, are introduced by the current and voltage transducers. This paper presents experimental results which show the impact of current transformers (CTs) on the accuracy of the harmonic power measurements. An expression for the evaluation of the power error in distorted conditions was developed which can be easily utilized in the case of linear current transducers. It is shown how CTs cannot be considered linear transducers and how the higher the …

instrument transformersEngineeringVoltage and current harmonicsSwitched-mode power supplyAcousticsActive powerTransducersEnergy Engineering and Power TechnologyLinear currentsPower factorHarmonic powerLinear transducersPower errorsPower transformersVoltage transducersHarmonic analysisHarmonic analysisMaximum valuesCurrent transformerElectrical and Electronic EngineeringPower measurementPhase anglesAbsolute valuesHarmonic power flowTotal harmonic distortionbusiness.industryElectric power distributionCurrent harmonicsElectrical engineeringAC powerCurrent transformerMV networksHarmonicsAccuracy classElectric instrument transformersHarmonicPower system harmonicsCurrent transformers (CTs) instrument transformerspower measurement power system harmonics.businessSettore ING-INF/07 - Misure Elettriche E Elettroniche